Temperature Controller modules

Item

R60TCTRT2TT2

R60TCRT4

R60TCTRT2TT2BW

R60TCRT4BW

Stocked Item

S

S

S

S

Certification

UL • cUL • CE

Control Output

Transistor output

Number of Temperature Input Points

4 channels/module

Applicable Thermocouple/Platinum Resistance Thermometer

R, K, J, T, S, B, E, N, U, L, PLII, W5Re/W26Re

Pt100, JPt100

R, K, J, T, S, B, E, N, U, L, PLII, W5Re/W26Re

Pt100, JPt100

Accuracy

Indication Accuracy

Ambient Temperature: 25±5°C

Full scale x (±0.3%)

Ambient Temperature: 
0 to 55°C

Full scale x (±0.7%)

Cold Junction Temperature Compensation Accuracy (Ambient Temperature: 0 to 55°C)

Temperature Process Value: -100°C or Higher

Within ±1.0°C

-

Within ±1.0°C

-

Temperature Process Value: -150 to -100°C

Within ±2.0°C

Within ±2.0°C

Temperature Process Value: -200 to -150°C

Within ±3.0°C

Within ±3.0°C

Sampling Cycle

Switchable between 250ms/4 channels and 500ms/4 channels

Control Output Cycle

0.5 to 100.0s

Input Impedance

1MΩ

Input Filter

0 to 100s (0: Input filter OFF)

Sensor Correction Value Setting

When the R mode is used (-(full scale of input range)) to full scale of input range) When the Q compatible function is used -50.00 to 50.00%

Operation at a Sensor Input Disconnection

Upscale processing

Temperature Control Method

PID ON/OFF pulse or two position control

PID Constants Range

PID Constants Setting

Setting by auto tuning is available.

Proportional Band (P)

When the R mode is used 0 (0.0) to full scale of input range (depending on the decimal point position) 
(0: two-position control) When the Q compatible function is used 0.0 to 1000.0% (0: Two-position control)

Integral Time (I)

0 to 3600s (Set 0 for P control and PD control.)

Derivative Time (D)

0 to 3600s (Set 0 for P control and PI control.)

Set Value Setting Range

Within the temperature range set in the thermocouple/platinum resistance thermometer to be used

Dead Band Setting Range

When the R mode is used 0 (0.0) to full scale of input range (depending on the decimal point position) When the Q compatible function is used 0.1 to 10.0%

Transistor Output

Output Signal

ON/OFF pulse

Rated Load Voltage

10 to 30VDC

Maximum Load Current

0.1A/point, 0.4A/common

Maximum Inrush Current

0.4A, 10ms

Leakage Current at OFF

0.1mA or lower

Maximum Voltage Drop at ON

1.0VDC (TYP) 0.1A, 2.5VDC (MAX) 0.1A

Response Time

OFF–ON: 2 ms or less, ON–OFF: 2 ms or less

Heater Disconnection Detection Specifications

Current Sensor

-

The following current sensors of URD, Ltd: CTL-12-S36-10 (0.0 to 100.0A), CTL-12-S56-10 (0.0 to 100.0A), CTL-6-P-H (0.00 to 20.00A), CTL-6-S-H (0.00 to 20.00A), CTL-12L-8 (0.0 to 100.0A)

Input Accuracy

Full Scale x (±1.0%)

Number of Alert Delay

3 to 255 times

Number of Occupied I/O Points

16 Points

32 Points

External Connection System

18-point terminal block

18-point terminal block x2

Applicable Solderless Terminal

R1.25-3 (The solderless terminal with an insulation sleeve cannot be used)

Internal Current Consumption

0.28A

0.31A

Weight (kg)

0.22

0.34

Base Unit Slots Occupied

1 slot

2 slots