MES Interface Module Functions
Model Number |
RD81MES96 |
|
Function |
DB Record Read/Write |
Reads/writes data in the database of the host information system |
Device Memory Read/Write |
Reads/writes device memory data of the CPU module |
|
Trigger Condition Monitoring |
Monitors values of the time or device tag components etc., and starts jobs when a trigger condition changes from false to true (the condition is satisfied) |
|
Data Operation and Processing |
Performs four arithmetic operations, obtains remainder, performs character string operation, etc. |
|
Program Execution |
Executes a program on the server through a MES Interface module |
|
DB Buffering |
Buffers the data sent to the database, and resend it after recovery, when the data cannot be linked due to the disconnection of the network between MES Interface module and the database or failure of the database etc. |
|
Setup Software: MES Interface Function Configuration Tool |
MX-MESIF-R-C1 (iQ-R Series MES Interface Configuration Tool Single License) |
High Speed Data Logger
Model Number |
RD81DL96 |
|
Stocked Item |
S |
|
Certification |
UL • cUL • CE |
|
Accessible CPU Modules |
iQ-R Series (Direct, Remote), Q Series (Remote), L Series (Remote) |
|
Data Sampling Interval |
High-speed Data Sampling (ms) |
Sequence scan time synchronization; 0.5...0.9, 1...32767 (for trigger logging); 2...32767 (for continuous logging) |
General Data Sampling (s) |
0.1...0.9, 1...32767; Time interval specification (specify hour/minute/second) |
|
Amount of Sampled Data |
High-speed Data Sampling |
Overall amount of data: 32768 (per setting: 1024); Overall number of device points: 32768 (per setting: 4096) |
General Data Sampling |
Overall amount of data: 65536 (per setting: 1024); Overall amount of data: 262144 (per setting: 4096) |
|
Function |
Data logging Logs CPU module device values at specified data sampling intervals. Event logging Monitors sampled device values from the CPU module, and logs events that occur. Report Outputs the data sampled by the high speed data logger module as an Excel® file. |
|
Recipe |
Executes the following operations using recipe files stored in the SD memory card: Transfer device values written on the recipe files to devices in the CPU module; Transfer device values in the CPU module to the recipe files. |
Transmission and Interface Specifications
Model Number |
RD81DL96 |
|||
Ethernet |
Interface |
1000BASE-T |
100BASE-TX |
10BASE-T |
Data Transmission Rate |
1 Gbps |
100 Mbps |
10 Mbps |
|
Transmission Method |
Base band |
|||
Number of Cascade Connections (When Using a Repeater Hub) |
– |
Maximum 2 stages |
Maximum 4 stages |
|
Maximum Segment Length |
100 m (distance between hub and node) |
|||
Supported Function |
Auto-negotiation (automatic recognition of communication speed/communication method) |
|||
IP Version |
IPv4 supported |
|||
SD Memory Card Slot |
Supply Power Voltage |
3.3 VDC |
||
Supply Power Capacity |
Up to 200 mA |
|||
Interface |
SD memory card/SDHC memory card |
|||
Number of Insertable Cards |
1 card |
|||
Number of Occupied I/O Points |
32 points (I/O assignment: Intelligent 32 points) |
|||
Clock |
Obtained from a CPU module (in multiple CPU system, CPU No.1). Time accuracy after obtaining the time, daily error of ±9.504 seconds |
|||
5VDC Internal Current Consumption |
1.1 A |
|||
External Dimensions (H x W x D) mm |
106 x 27.8 x 110 |
|||
Weight (kg) |
0.24 |